Search results for " Chromatography"
showing 10 items of 2200 documents
Model compound synthesis for the structure determination of new unknown planar aromatic compounds originating from pulp mill
1991
Abstract Several model compounds have been synthesized for verification of the structures of new unknown planar aromatic compounds (UPACs) observed in high-resolution gas chromatography/low-resolution mass spectrometry analyses of the polychlorodibenzodioxins (PCDDs) and polychlorodibenzofurans (PCDFs) in pulp mill products, effluents, sediments and mussels. The mass spectra of synthetic alkyl polychlorodibenzofurans (C6-PCDFs) were different, but those of alkyl polychlorobibenzyls (C5-PCBBs) were very similar compared to the spectra of UPACs.
Thin-layer chromatography of phenoxyacetic acid herbicides
1981
Thin-layer chromatography of 2-methyl-4-chlorophenoxyacetic acid and its soil metabolites
1980
Abstract The thin-layer chromatography of 2-methyl-4-chlorophenoxyacetic acid, 4-chloro- o -cresol and 3-methyl-5-chlorocatechol and their pentafluorobenzyl derivatives has been studied on silica gel as adsorbent with 19 solvent systems. The best separation of the individual components occurred with toluene-benzene-acetic acid (2:2:1). Chloroform-diethyl ether-toluene (1:1:1) was suitable for the group separation of the pentafluorobenzyl derivatives.
Development of a liquid chromatography–tandem mass spectrometry for the determination of enniatins in biological samples from Wistar rats
2014
Application of matrix solid phase dispersion to the determination of imidacloprid, carbaryl, aldicarb, and their main metabolites in honeybees by liq…
2005
Abstract A method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and dichloromethane–methanol as eluent and liquid chromatography–atmospheric pressure chemical ionization–mass spectrometry (LC–APCI–MS) has been developed for the simultaneous determination of imidacloprid, 6-chloronicotinic acid, carbaryl, aldicarb, aldicarb sulfoxide, and aldicarb sulfone in honeybees. The proposed method was compared with liquid–liquid extraction (LLE) combined with LC–APCI–MS analysis. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. Recovery studies were performed at different fortification levels. Average re…
Identification of 5,6,7,8-tetrahydropterin and 5,6,7,8-tetrahydrobiopterin in Drosophila melanogaster.
1988
Summary Using reversed-phase high-performance liquid chromatography with electrochemical detection we have demonstrated the occurrence of 5,6,7,8-tetrahydropterin and 5,6,7,8-tetrahydrobiopterin in Drosophila melanogaster . The former is the first time that has been detected in vivo . The identification has been based on the retention times, hydrodinamic voltagrams and the differential concentration in three strains of Drosophila melanogaster . Compared to the wild type, the Punch 2 mutant has diminished levels of both pteridines, whereas Henna-recessive 3 lacks completely tetrahydropterin and has increased levels of tetrahydrobiopterin, as expected according to their biochemical lesions.
Comparative column chromatographic estimations of phenylalanine in plasma, whole blood, native and paper-dried capillary blood of healthy children an…
1984
The concentration of phenylalanine in plasma, whole venous and capillary blood, and paper-dried blood of 75 probands (25 healthy adults, 27 healthy children, and 23 patients with hyperphenylalaninaemia) were measured by use of a sensitive short column chromatography method. The comparison of the values in each group of probands by several statistic methods showed an excellent correlation of the phenylalanine concentration in paper-dried whole blood to those measured in venous plasma. Evaluation of the analytical method revealed a high sensitivity and accuracy by use of a sample volume of 50 microliter. We would therefore suggest that the estimation of phenylalanine for the diagnosis and the…
Analysis of LSD in human body fluids and hair samples applying ImmunElute columns.
2000
Immunoaffinity extraction units (LSD ImmunElute) are commercially available for the analysis of lysergic acid diethylamide (LSD) in urine. The ImmunElute resin contains immobilized monoclonal antibodies to LSD. We applied the ImmunElute procedure to serum and also to human hair samples. For hair analysis the samples were first extracted with methanol under sonication. The extracts were then purified using the ImmunElute resin. LSD analysis was carried out with HPLC and fluorescence detection. The immunoaffinity extraction provides highly purified extracts for chromatographic analysis. The limit of detection (signal-to-noise ratio = 3) has been determined to be < 50 pg regardless of which sa…
Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring
2017
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …
Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.
2011
There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…